Pure Aluminum Round Rod
Φ9.5/12/15mm; conductivity ≥61% IACS; tensile 96-150 MPa; elongation ≥8%; GB/T 3954-2014, ASTM B233; 50,000 t/year
Quote thisFactory-direct supply of electrical aluminum rod, alloy cable and overhead conductors, backed by State Grid and Southern Grid certification and a closed-loop low-carbon production chain.
Supplier-declared, pending confirmation

Φ9.5/12/15mm; conductivity ≥61% IACS; tensile 96-150 MPa; elongation ≥8%; GB/T 3954-2014, ASTM B233; 50,000 t/year
Quote this
Φ9.5/12mm; conductivity ≥62.5% IACS; tensile 60-120 MPa; elongation ≥10%; GB/T 3954-2014; 10,000 t/year
Quote this
Φ9.5/12mm; conductivity ≥52.5% IACS; tensile 110-170 MPa; elongation ≥8%; GB/T 3954-2014, ASTM B230; 20,000 t/year
Quote this
Φ9.5/12mm; conductivity ≥53% IACS; tensile 295-360 MPa; elongation ≥3%; GB/T 3954-2014, ASTM B396; 8,000 t/year
Quote this
16-800 mm²; 7/19/37/61 wires; tensile 160-200 MPa; GB/T 1179-2017, IEC 61089, ASTM B232; 10kV-500kV lines; 30,000 t/year
Quote this
Al section 16-800 mm²; steel core 3-100 mm²; rated breaking force 4.1-178 kN; GB/T 1179-2017, IEC 61089, ASTM B232; 25,000 t/year
Quote this
100-800 mm²; 6201-T81 alloy; wire tensile 295 MPa; conductivity ≥53% IACS; GB/T 1179-2017, IEC 61089; 10,000 t/year
Quote this
240-720 mm²; continuous 150°C, short-term 180°C; conductivity ≥60% IACS; ampacity increase ~60%; GB/T 26270-2010, DL/T 632; 5,000 t/year
Quote this
16-300 mm²; Al / Al alloy conductor; XLPE insulation; 90°C; GB/T 14049-2008, IEC 60502; 15,000 t/year
Quote this
10-300 mm²; 0.6/1kV; Al / Al alloy conductor; XLPE / PVC; 1-4 cores; GB/T 12527-2008, IEC 60502; 20,000 t/year
Quote this
2×16 ~ 4×120 mm²; 0.6/1kV; aluminum conductor; XLPE; GB/T 12527-2008, JB/T 10934; 8,000 t/year
Quote this
10-400 mm²; 8000 series Al alloy conductor; XLPE insulation, PVC sheath; 90°C; GB/T 12706-2020, IEC 60502-1; 20,000 t/year
Quote this
16-400 mm²; steel tape or interlocked Al alloy armor; PVC / LSZH sheath; direct burial; GB/T 12706-2020; 10,000 t/year
Quote this
35-630 mm²; 1C/3C; 8000 series Al alloy; XLPE; copper tape screen; GB/T 12706-2020, IEC 60502-2; 6,000 t/year
Quote this
10-400 mm²; FR class ZA/ZB/ZC/ZR; NH-A/NH-B; LSZH option; GB/T 19666-2019, GB/T 12706-2020, BS 6387; 5,000 t/year
Quote this
144 cells (182mm); efficiency 21.0-21.5%; 2278×1134×35mm; 27.5kg; IEC 61215/61730, UL 61730; 2 GW/year
Quote this
144 cells (182mm); rear gain 10-30%; efficiency 21.3-22.0%; 2.0+2.0mm glass; IEC 61215/61730, UL 61730; 1 GW/year
Quote this
144 cells (182mm); efficiency 22.5-23.3%; temp coefficient -0.30%/°C; 2278×1134×35mm; IEC 61215/61730, UL 61730; 3 GW/year
Quote this
144 cells (182mm); rear gain 15-35%; efficiency 23.1-23.9%; bifacial ratio ≥85%; IEC 61215/61730, UL 61730; 2 GW/year
Quote this
132 cells (210mm); efficiency 22.8-23.5%; Voc 55.8V; IEC 61215/61730, UL 61730; 2 GW/year
Quote this
Efficiency 25.0-25.8%; fill factor 83.5-84.5%; thickness 150μm; IEC 61215, enterprise standard; 5 GW/year
Quote this
6063-T5 alloy; anodized or electrophoretic coating; oxide film ≥15μm; height 35/40/50mm; GB/T 5237-2017, IEC 61215; 50,000 t/year
Quote this
Corner brackets, clamps, grounding clips, drain plugs; 6063-T5 / 304 stainless steel; corner strength ≥2000N; GB/T 5237-2017
Quote this
6061-T6 / 6005A-T6; wind resistance 36.9m/s; service life ≥25 years; corrosion class C4/C5; GB 50797-2012; 30,000 t/year
Quote this
6063-T5 / 6061-T6; anodized; self-weight 3-5 kg/m²; clamp, block or embedded installation; GB 50797-2012; 20,000 t/year
Quote this
HDPE float; 6061-T6 bracket; wind-wave class 6; float life ≥25 years; UL94-HB; GB 50797-2012; 5,000 t/year
Quote this
Survey, design, procurement, construction, grid connection; system efficiency ≥83%; 10yr product / 25yr power warranty; 500 MW/year
Quote this
Feasibility to O&M; mountain, flat, water, agri-PV; system efficiency ≥85%; duration 3-12 months; 1 GW/year
Quote this
Inspection, cleaning, repair, 24/7 remote monitoring; availability ≥98%; fault response ≤4 hours; 2 GW O&M scale
Quote this
10kV(12kV) 630/1250A, 50-300 mm², 42kV/75kV, 20kA; 20kV(24kV) 630/1250A, 70-400 mm², 50kV/125kV, 20kA; 35kV(36kV) 630/1250A, 95-400 mm², 70kV/170kV, 25kA; EPDM insulation; RMU / box transformer connection; GB/T 12706.4, IEC 60502
Quote this
10kV(12kV) 630/1250A, 50-300 mm², 42kV/75kV, 20kA; 20kV(24kV) 630/1250A, 70-400 mm², 50kV/125kV, 20kA; 35kV(36kV) 630/1250A, 95-400 mm², 70kV/170kV, 25kA; EPDM; T-branching with front connector; GB/T 12706.4, IEC 60502
Quote this
10kV(12kV) 50-300 mm², 42kV/75kV, 20kA; 20kV(24kV) 70-400 mm², 50kV/125kV, 20kA; 35kV(36kV) 95-400 mm², 70kV/170kV, 25kA; 630/1250A; EPDM; one-in two-out branching, cable branch box; GB/T 12706.4, IEC 60502
Quote this
10kV(12kV) and 20kV(24kV); 200/400A; 50-300 mm² (10kV), 70-400 mm² (24kV); 12.5kA; EPDM; pad-mount / pole-mount switch; GB/T 12706.4
Quote this
10kV(12kV) 50-300 mm², 20kA; 20kV(24kV) 70-400 mm², 20kA; 35kV(36kV) 95-400 mm², 25kA; 630/1250A; EPDM + ZnO varistor; lightning and overvoltage protection; GB/T 12706.4, IEC 60099
Quote this
10kV(12kV) 42kV/75kV; 20kV(24kV) 50kV/125kV; 35kV(36kV) 70kV/170kV; EPDM; seals spare socket, insulation and waterproof; GB/T 12706.4
Quote this
10kV(12kV) 630A, 50-300 mm², 42kV/75kV, 20kA; EPDM + electronic module; integral short-circuit/earth fault indicator; GB/T 12706.4, IEC 60502
Quote this
10kV(12kV) 630/1250A, 50-400 mm², 42kV/75kV, 20kA; silicone rubber; switchgear / transformer indoor termination; GB/T 12706.4, IEC 60502
Quote this
10kV(12kV) 630/1250A, 50-400 mm², 42kV/75kV, 20kA; XLPE; economical indoor switchgear termination; GB/T 12706.4, IEC 60502
Quote this
20kV(24kV) 70-400 mm², 50kV/125kV, 20kA; 35kV(36kV) 95-400 mm², 70kV/170kV, 25kA; 630/1250A; EPDM; GB/T 12706.4, IEC 60502
Quote this
10kV(12kV) 630/1250A, 50-400 mm², 42kV/75kV, 20kA; silicone rubber; overhead line connection, anti-pollution; GB/T 12706.4, IEC 60502
Quote this
10kV(12kV) 630/1250A, 50-400 mm², 42kV/75kV, 20kA; XLPE; economical outdoor pole termination; GB/T 12706.4, IEC 60502
Quote this
35kV(36kV) 1250A, 95-400 mm², 70kV/170kV, 31.5kA; EPDM; GIS gas-insulated switchgear plug-in connection; IEC 60502, IEC 62271
Quote this
10kV(12kV) 630/1250A, 50-400 mm², 42kV/75kV, 20kA; silicone rubber; same-section cable jointing; GB/T 12706.3, IEC 60502
Quote this
10kV(12kV) 630/1250A, 50-400 mm², 42kV/75kV, 20kA; XLPE; economical same-section straight joint; GB/T 12706.3, IEC 60502
Quote this
10-35kV; 50-400 mm²; tinned copper; cable sheath/shield earthing connection; GB/T 12706
Quote this
10-35kV; polyurethane (PU); joint/termination waterproof sealing, outdoor moisture-proof; GB/T 12706
Quote this
10-35kV; 630/1250A; 50-400 mm²; Cu-Al composite; cable conductor to equipment terminal; GB/T 14315
Quote this
10-35kV; 50-400 mm²; semi-conductive material; electric field stress control at termination/joint; GB/T 12706
Quote this
10-35kV; 50-400 mm²; stainless steel; shield layer fixing, constant pressure grip; GB/T 12706
Quote this
Produced via continuous casting and rolling; used as feedstock for cable and conductor drawing
Quote this
Aluminum alloy conductor cable for power transmission and distribution
Quote this
Stranded aluminum or aluminum alloy conductor for overhead power lines; State Grid and Southern Grid qualified
Quote this

Hardware and fittings for power transmission and distribution infrastructure
Quote this
Recycled aluminum alloy billets and industrial extrusions for power equipment structural parts (produced by subsidiary Qiangsheng Aluminum Precision Mfg.)